TABLE 4

 
 

Results of Abrasion and Coating Weight Testing for 2024-T3 Aluminum Alloy For Low Voltage DC+AC Process
(Sulfuric acid with organic additive. 12VDC, 50 amps/sq. ft.)

 
 
 
Electrolyte Thickness
(mil)
Weight Loss
mg
Coating Weight
(mg/ft²/mil)
Average for 84-month period
Concent.g/L T°F Weight loss
mg
Coating weight
(mg/ft²/mil)
300 40 2.07 9.3 2.389 14.38 2.18
300 55 2.21 10.2 2.25 +/- = .467 +/- = .467
200 70 1.00 10.8 2.32
 
 
Available Through Authorized Sanford Licensees
 
 
SANFORD PROCESS™ CORPORATION
1 Shorr Court, Woonsocket, RI 02895
Tel: (401) 597-5000 Fax: (401) 597-5485
Owners of Patents of the World's Finest Hard Anodized Process

 

 

 
 
 
Copyright © 2000 Sanford Process
Site designed by WorldWideWebWorks
 
 
 

 